With its performance spectrum, the automatic titrator TitroLine® 7000 is the ideal starting device for all potentiometric titrations with potential for expansion and automation.
Thanks to the high-resolution and precise pH/mV and “dead-stop” measuring interface, it is possible to determine a wide range of parameters quickly, reliable and accurate. The easy exchangeable burette heads with a size of 5, 10, 20 and 50 allows a quick change between the different titrants.

The TitroLine® 7000 with has an exceptional high visibility full color graphic display which allows viewing even at extreme angles. The titration curve, but also other information such as ml, pH/mV/µA and temperature are clearly displayed on the display.

Specifications

Measuring input analog pH/mV-input with 24 bit transducer. Electrode socket according to DIN 19 262 or BNC with RFID receiver for SI Analytics ID electrodes
Measuring range pH/accuracy – 3.0… 18.00 / 0.002 +/- 1 digit
Measuring range mV/accuracy – 2000…2000/ 0.1 +/- 1 digit
Measuring input µA: μA-connector for double platinum electrodes, connection: 2 x 4 mm – sockets), polarisation voltage variably adjustable
Measuring input temperature: Connector for Pt 1000 / NTC 30 KOhm ( connection: 2 x 4 mm – sockets)
Measuring range temperature Pt 1000 – 75…195 °C    / NTC 30 KOhm – 40 …125 °C
Interfaces 3 × USB (2 x USB-A and 1 × USB-B), 2 × RS-232-C and 1 x LAN
Interchangeable burettes 5, 10, 20 ml or 50 ml intelligent interchangeable burette units
Resolution (Steps) 20.000 steps
Dosing accuracy according to DIN ISO 8655, part 3:
accuracy: < 0.15 %
precision: < 0.05 – 0.07 % (in dependence of the used burette size)

Key features

  • Automatic wireless recognition of SI Analytics ID electrodes guarantee accurate calibration and measurements
  • High resolution pH/mV-electrode and temperature inputs for pH, ISE, redox (ORP) or photometric titrations.
  • Perfect for non-aqueous titration such as acid and base numbers in oils (TAN and TBN)
  • Polarizable electrode input for set endpoint titrations („Dead-stop“)
  • Linear (fixed increment) and dynamic equivalence point titration mode and titration to endpoints
  • pH Stat titrations
  • Single and continuous measuring function
  • Default methods for many different applications such alkalinity, total hardness, total acidity in drinks, chloride, SO2, TAN, TBN and many others.
  • Formula editor for individual calculations
  • Titrations with the photometric sensor OptiLine 6
  • Dosing with up to two connected piston burettes per method
  • Titration with external piston burette

Also available

For more information about the different models, please contact us. We can look at which titrator is best suited for your application.

The TitroLine® 5000, a very compact titrator for simple routine titrations. Thanks to a selection of standard methods to choose from, the creating of methods as you go is no longer required.

Karl Fischer Titrator. TitroLine® 7500 KF for volumetric and TitroLine® 7500 KF trace for coulometric titrations

Universal Titrator. TitroLine® 7750 and TitroLine® 7750 KF for all types of potentiometric, vol. KF and dead-stop-titrations

Universal titrator with IDS-technology. TitroLine® 7800 for all potentiometric, vol. KF and dead-stop-titrations. Additionally with IDS-measuring input

Sample changer for titration. TW 7200 for up to 38 and TW 7450 for up to 72 samples