a
Wilten Instruments has a wide range of instruments. Because of the variety of options on some products we are not able to mention all of them on our website. Complete information is available on demand.
Mon - Fri: 8:30AM - 5:00PM
+ (31) 076 508 65 00

CS-700/720

Home  /  Colour Measurement  /  CS-700/720

Color and Haze meter

Suitable for one-stop measurement solution of color, haze, spectral transmittance and total transmittance of transparant and translucent materials such as plastic, film, glass, LCD panel and touchscreen.

  • Follow ASTM and ISO standards
  • It has a comprehensive color measurement function in the industry
  • Standard computer data analysis and management software
  • 7-inch Android touch screen
  • Open sample bin
  • Provide abundant measuring fixtures

Type CS-700 CS-720
Light Source Haze / Transmittance:CIE-A,CIE-C,CIE-D65
Chromaticity index:A,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CMF,U30,DLF,NBF,TL83,TL84
Standards ASTM D1003/D1044,ISO13468/ISO14782 JIS K 7105,JIS K 7361,JIS K 7136,GB/T 2410-08,CIE No.15,
ISO 7724/1,ASTM E1164,DIN 5033,Teil7,JIS Z8722,Condition c standard
Parameters

Haze (HAZE),Transmittance (T),Spectral transmittance,
CIE Lab, LCh, CIE Luv, XYZ, Yxy, , Hunter Lab Munsell MI,CMYK,
Whiteness WI(ASTM E313-00,ASTM E313-73, CIE/ISO, Hunter,
Taube Berger Stensby),Yellow Index YI(ASTM D1925, ASTM
E313-00, ASTM E313-73), Tint(ASTM E313-00), Heterochromatic
index Milm, APHA, Pt-Co(Index of platinum cobalt), Gardner,
Color difference (ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),
ΔE*cmc(1:1),ΔE*94,ΔE*00)

Haze (HAZE),Transmittance (T),Spectral transmittance,Clarity
CIE Lab, LCh, CIE Luv, XYZ, Yxy, , Hunter Lab Munsell MI,CMYK,
Whiteness WI(ASTM E313-00,ASTM E313-73, CIE/ISO, Hunter,
Taube Berger Stensby),Yellow Index YI(ASTM D1925, ASTM
E313-00, ASTM E313-73), Tint(ASTM E313-00), Heterochromatic
index Milm, APHA, Pt-Co(Index of platinum cobalt), Gardner,
Color difference (ΔE*ab,ΔE*CH,ΔE*uv,ΔE*cmc(2:1),
ΔE*cmc(1:1),ΔE*94,ΔE*00)
Spectral Response CIE The spectrum functionY/V(λ)
Wavelength 400-700nm
Wavelength Interval 10nm
Geometry 0/d
Measurement Area/Sample Port 16.5mm/21mm 18mm/25.4mm
Measurement Range 0-100%
Haze Resolution 0.01
Haze Repeatability Haze<10%, Repeatability≤0.05;Haze≥10%, Repeatability≤0.1%;Transmittance≤0.1%
Sample Size Thickness ≤145mm
Display 7 Inches Touch Screen
Memory Mass storage
Interface USB
Power 220V
Working Temperature 5~40℃,Relative humidity 80% or below (at 35 ° C), no condensation
Storage Temperature -20℃~45℃,Relative humidity 80% or below (at 35 ° C), no condensation